D6 - Range Of Diffusers
The D6 diffuser offers greatest throughput in the UV.
Spectral Range of use: 200-600nm
Spectral Range of use: 200-600nm
 
 
 
D7 - Range Of Diffusers
The D7 diffuser serves a very broad spectral area and is universally applicable.
Spectral Range of use: 200-1100nm
Spectral Range of use: 200-1100nm
 
 
 
UV-J1002: Global Entrance Optic
CMS has designed a new global entrance optic for measuring spectral UV irradiance. The system provides a considerably improved measurement accuracy in comparison to traditional optics and is deigned for use with lightguides. The cosine error is less than 3 % for incidence angles between 0° an 70°.
The calibration can be done by applying the KS-J1011 portable spectral irradiance source and the appropriate adapter (KS-J1011-ADAPT-GLO).
The calibration can be done by applying the KS-J1011 portable spectral irradiance source and the appropriate adapter (KS-J1011-ADAPT-GLO).
 
 
 
UV-J1002-REG: Global Entrance Optic
The new design of the reliable global entrance optic UV-J1002 for measuring spectral UV irradiance. The optic offers an temperature regulation with an internal heating element.
The calibration can be done by applying the KS-J1011 portable spectral irradiance source and the appropriate adapter (KS-J1011-ADAPT-GLO).
The calibration can be done by applying the KS-J1011 portable spectral irradiance source and the appropriate adapter (KS-J1011-ADAPT-GLO).
 
 
 
UV-J1003: Global Entrance Optic
The special design of the reliable global entrance optic UV-J1002 for measuring spectral UV irradiance. The optic offers an internal shutter.
The calibration can be done by applying the KS-J1011 portable spectral irradiance source and the appropriate adapter (KS-J1011-ADAPT-GLO).
The calibration can be done by applying the KS-J1011 portable spectral irradiance source and the appropriate adapter (KS-J1011-ADAPT-GLO).
 
 
 
UV-J1015: Global Entrance Optic
The global entrance optic is designed for the double Brewer spectrophotometer. The cosine error is less than 6 % for incidence angles between 0° an 80°. The systematic uncertainties of global solar irradiance measurements with this new entrance optic are considerably reduced compared with measurements with the traditional flat diffuser.
 
 
 
IS-J1018: Integating Sphere
CMS offers a wide range of integrating spheres in the raw sphere shape. Prototyping as well as series production demands are well satisfied with this system. The standard diameters available are ranging from 30 mm up to 500 mm. Other diameters are available on request.
 
 
 